The Industrial-Duty (ID) series of Glideforce linear actuators by Concentric International (formerly Iowa Export-Import) are powerful 12V DC gearmotors that use an acme screw drive or ball screw drive to move a shaft back and forth along its length. The shaft will hold its position even when unpowered. The versions with acme screw drives (part number LACTx-500Ax) can move loads up to 250 kgf [550 lbs or 2500 N] and withstand static loads up to 450 kgf [1000 lbs or 4500 N], while versions with more efficient ball screw drives (part number LACTx-1000Bx) can move loads up to 450 kgf [1000 lbs or 4500 N] and withstand static loads up to 1360 kgf [3000 lbs or 13,600 N].
Two limit switches safely stop the motor at either end of its range, while integrated diodes allow it to reverse direction after reaching a limit point if the supplied voltage is reversed, and a built-in overload clutch protects the actuator from excessive dynamic loads. The actuators have an all-steel frame and extension tube, and the entire case is sealed to protect against dust and water (rated IP65).
These actuators are available in a variety of stroke lengths, from 4″ to 24″, and with optional potentiometers that are linked to the shaft position, for use in feedback systems:
Actuator Type |
Max Dynamic Load |
No-Load Speed @ 12 V |
Max-Load Speed @ 12 V |
Current Draw @ 12 V |
Nominal Stroke Length |
With Feedback |
Without Feedback |
---|---|---|---|---|---|---|---|
Industrial-Duty (ID) with Acme screw drive |
250 kgf [550 lbs] |
1.7 cm/s [0.66″/s] |
1.4 cm/s [0.56″/s] |
2.4 A – 13.2 A |
4″ | LACT4-500APL | LACT4-500AL |
6″ | LACT6-500APL | LACT6-500AL | |||||
8″ | LACT8-500APL | LACT8-500AL | |||||
12″ | LACT12-500APL | LACT12-500AL | |||||
18″ | LACT18-500APL | LACT18-500AL | |||||
24″ | LACT24-500APL | LACT24-500AL | |||||
Industrial-Duty (ID) with ball screw drive |
450 kgf [1000 lbs] |
1.7 cm/s [0.66″/s] |
1.4 cm/s [0.56″/s] |
2.4 A – 13.2 A |
4″ | LACT4-1000BPL | LACT4-1000BL |
6″ | LACT6-1000BPL | LACT6-1000BL | |||||
8″ | LACT8-1000BPL | LACT8-1000BL | |||||
12″ | LACT12-1000BPL | LACT12-1000BL | |||||
18″ | LACT18-1000BPL | LACT18-1000BL | |||||
24″ | LACT24-1000BPL | LACT24-100 |
Heavy-duty mounting brackets made from machined aluminum or stamped steel are available for attaching the actuators to a structure; two are required for each actuator. A mounting clevis is also available for converting either actuator end into a clevis-style.
Details for item #3632
ID series features and specifications
The following specifications apply to all Glideforce ID series linear actuators with the standard 20:1 gear ratio
Dimensions
A dimension diagram of the ID linear actuators are shown below. It applies both to versions with limit switches (500AL and 1000BL) and to versions with limit switches and potentiometers (500APL and 1000BPL), though note that the actual stroke length is affected by the kind of drive screw (acme or ball). For more detailed information, including the retracted and extended lengths of each version, see the datasheet.
Dimensions of Glideforce ID linear actuators with limit switches (LACTx-500AL, LACTx-500APL, LACTx-1000BL, and LACTx-1000BPL). Units are mm. |
---|
Using the actuator
Glideforce LACT4 industrial-duty linear actuator (4″ stroke) with shaft fully extended. |
---|
To test-drive the actuator, connect a power source of up to 12 V to the motor leads while ensuring that the output shaft is not allowed to rotate relative to the actuator body as it extends or retracts. Reversing the applied voltage will reverse the direction of motion. A motor controller or motor driver is required for electronic speed and direction control. We recommend our Jrk G2 24v21 Motor Controllers for use with the feedback actuators (see below for more information on this) and the Simple Motor Controller G2 24v19 for controlling the actuators without feedback, though many of our other motor controllers and motor drivers are capable of powering this actuator.
These actuators have a stall current of approximately 50 A at 12 V, but they will, on average, draw far less than this when used within their load ratings. They draw around 2.4 A with no load and can exceed 13 A at their maximum rated dynamic load. However, please note that the actuators can briefly draw close to their full stall current when abruptly started or on a sudden change of direction. Such current spikes can be dampened if you take steps to limit the acceleration of the actuator (many of our motor controllers offer optional acceleration limiting).
The ID linear actuators have a 10″ (25 cm) cable ending in unterminated,stripped wires. The thick red and black wires are the motor leads. Actuators with feedback potentiometers have three additional thinner wires: white, yellow, and blue. White and yellow connect to the two ends of the 10 kΩ potentiometer, and blue connects to the wiper. If you connect white to ground and yellow to VCC, you can then read the voltage on blue to determine the position of the actuator (the voltage will increase from close to 0 V to close to VCC as the actuator goes from fully retracted to fully extended). The picture below shows the end of the cable for an ID linear actuator with feedback:
|
|
These actuators are not compatible with our extension cable for LD/MD linear actuators.
Using a Jrk G2 motor controller with a linear actuator with feedback
Connecting an industrial-duty linear actuator with feedback to a Jrk 24v13 motor controller. |
---|
The feedback features of our Jrk G2 24v21 motor controller make it a great solution for precisely controlling our linear actuators with feedback. Our settings file for the Jrk G2 configuration utility makes setup easy, eliminating the need to tune the PID constants. To get started, follow the steps below:
Dimensions
Nominal stroke length: | 18 in |
---|---|
Actual stroke length: | 17.56 in |
Retracted length: | 30.83 in |
Extended length: | 48.39 in |
Weight: | 6.5 kg |
General specifications
Gear ratio: | 20:1 |
---|---|
Screw type: | ball |
Current @ 12V, no load: | 2.4 A |
Current @ 12V, max load: | 13.2 A |
Stall current @ 12V: | 50 A1 |
Linear speed @ 12V, no load: | 0.66 in/s |
Linear speed @ 12V, max load: | 0.56 in/s |
Max linear force @ 12V: | 1000 lb2 |
Maximum duty cycle: | 25%3 |
Feedback potentiometer included?: | Y |
Limit switches included?: | Y |
Overload clutch included?: | Y |
Minimum operating temperature: | -25.0 °C |
Maximum operating temperature: | 65 °C |
IP rating: | IP654 |